Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load

Product Details
Application: Power, Electronic
Cooling Method: Dry-type Transformer
Winding Type: Auto-transformer
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
15
Year of Establishment
2014-12-15
  • Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
  • Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
  • Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
  • Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
  • Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
  • Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Working Environment
  • Product productive process
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
dry type transformer
Certification
ISO9001, CCC
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
Brand
None
Warranty
2 Years
Standard
IEC/GB
Brand Name
Customized
Material
Copper/Aluminum
Coil Structure
Auto Transformer
Transport Package
Wooden
Origin
China
HS Code
8504319000
Production Capacity
1000/Per Month

Product Description

Product Description
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Dry-immersed Type Transformer
Dry-type transformer has many types you can to choose. They have epoxy resin cast dry-type transformer, non-encapsulated dry type transformer, amorphous alloy dry type transformer, three-dimensional wound core dry-type transformer.
Dry-type transformer is a high-performance electrical equipment. It adopts advanced insulation technology, does not require oil immersion, and is safe and environmentally friendly. It is fireproof and explosion-proof, and its operation is stable and reliable.
Specification
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Model
Rated capacity(KVA)
connection symbol
High voltage
Tapping range
Low voltage
no-load loss(W)
load loss(W)
no-load current(%)
Short circuit resistance
SC10-30
30
Yyn0  or Dyn11
10
±5%
0.4
190
1320
2.0
4.0
SC10-50
50
Yyn0  or Dyn11
10
±5%
0.4
270
1700
2.0
4.0
SC10-80
80
Yyn0  or Dyn11
10
±5%
0.4
370
1880
1.5
4.0
SC10-100
100
Yyn0  or Dyn11
10
±5%
0.4
400
1570
1.5
4.0
SC10-125
125
Yyn0  or Dyn11
10
±5%
0.4
470
1850
1.3
4.0
SC(B)10-160
160
Yyn0 or Dyn11
10
±5%
0.4
540
2130
1.1
4.0
SC(B)10-200
200
Yyn0 or Dyn11
10
±5%
0.4
620
2760
1.1
4.0
SC(B)10-250
250
Yyn0 or Dyn11
10
±5%
0.4
720
3470
1.0
4.0
SC(B)10-315
315
Yyn0  or Dyn11
10
±5%
0.4
880
3990
1.0
4.0
SC(B)10-400
400
Yyn0 or Dyn11
10
±2×2.5%
0.4
980
4880
1.0
4.0
SC(B)10-500
500
Yyn0 or Dyn11
10
±2×2.5%
0.4
1160
5860
0.85
4.0
SC(B)10-630
630
Yyn0 or Dyn11
10
±2×2.5%
0.4
1340
6860
0.85
4.0
SC(B)10-800
800
Yyn0 or Dyn11
10
±2×2.5%
0.4
1520
8130
0.85
6.0
SC(B)10-1000
1000
Yyn0 or Dyn11
10
±2×2.5%
0.4
1770
9690
0.85
6.0
SC(B)10-1250
1250
Yyn0 or Dyn11
10
±2×2.5%
0.4
2090
11400
0.85
6.0
SC(B)10-1600
1600
Yyn0 or Dyn11
10
±2×2.5%
0.4
2450
14700
0.70
6.0
SC(B)10-2000
2000
Yyn0 or Dyn11
10
±2×2.5%
0.4
3050
17170
0.70
6.0
Model
Main Machine Dimensions (L×B×H)mm
Track Gauge(mm*Y)
Outer Shell Dimensions (Length×Width×Height, mm)
Weight(KG)
SC10-30/10
696×500×790
400×450
1100×1000×1500
276
SC10-50/10
746×500×827
400×450
1100×1000×1500
371
SC10-80/10
826×600×868
400×550
1150×1000×1500
461
SC10-100/10
868×600×905
400×550
1150×1000×1500
563
SC10-125/10
995×710×913
550×660
1250×1050×1500
659
SC(B)10-160/10
976×710×878
550×660
1350×1050×1600
741
SC(B)10-200/10
1026×710×940
550×660
1350×1100×1600
883
SC(B)10-250/10
1084×800×945
660×750
1400×1200×1700
1066
SC(B)10-315/10
1146×800×975
660×750
1500×1300×1700
1325
SC(B)10-400/10
1176×800×1040
660×750
1550×1300×2200
1498
SC(B)10-500/10
1260×800×1103
660×750
1600×1300×2200
1812
SC(B)10-630/10 4%
1296×800×1085
660×750
1700×1350×2200
1793
SC(B)10-630/10 6%
1384×870×1118
820×820
1750×1350×2200
2398
SC(B)10-800/10
1417×870×1205
820×820
1850×1400×2200
2680
SC(B)10-1000/10
1590×870×1315
820×820
1970×1450×2200
3341
SC(B)10-1250/10
1674×870×1506
820×820
2050×1480×2200
4128
SC(B)10-1600/10
1756×1050×1768
1070×1000
2050×1450×2200
4896
SC(B)10-2000/10
1674×870×1506
820×820
2050×1480×2200
4128
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Product Advantage
1. No oil, no pollution, flame retardant, self-extinguishing and fire prevention.
2. Low loss, high efficiency and low noise. It can run long time under 125% rated load under the forced air-cooling condition and is equipped with intelligent temperature controller. The functions of fault alarm, over temperature  alarm, over temperature trip and black gate. It is connected with computer through RS485 serial interface and achieves centralized monitoring and control.
3. Small local discharge (under 30 PC) and high reliability, can ensure long-term safe operation, life up to 30 years.
4. Resistance to crack and temperature change, high mechanical strength, strong ability to resist sudden short-circuit.
5. Good moisture-proof property, it can run normally under 100% humidity and can be put into operation without drying treatment after shutdown.
6. There is no need for a separate transformer room, core maintenance or load-bearing beam  saving civil land and occupation No oil, so it will not produce toxic gas to pollute the environment.  No need of oil collecting pits or other ancillary buildings which reduces the cost of construction Easy installation, no debugging, almost no maintenance; No need to replace or check the oil, low operation and maintenance cost.
Working Environment
Dry-type transformers thrive in indoor, moderate-climate, fire-sensitive, and low-contamination environments, prioritizing safety, space efficiency, and compliance with strict regulatory standards. Their air-cooled design and non-flammable materials make them the preferred choice for urban, commercial, and sensitive applications, while technical adaptations (IP ratings, insulation classes) extend their usability across diverse but non-extreme operational conditions.
Working Environments for Dry-Type Transformers
Dry-type transformers, distinguished by their air-cooled, oil-free design, are engineered for versatility in diverse operational settings where safety, space efficiency, and environmental compatibility are critical. Their typical working environments include:
1. Indoor & Enclosed Spaces
Dry-type transformers excel in indoor applications due to their non-flammable nature (no insulating oil), making them ideal for:
Commercial/Residential Buildings: Installed in basements, utility rooms, or rooftop enclosures of offices, apartments, and shopping centers, where fire safety codes restrict oil-filled equipment.
Data Centers & Server Rooms: Requiring clean, low-risk power solutions, these transformers operate in controlled environments with strict temperature (20–25°C) and humidity (40–60%) controls to prevent dust and moisture-related failures.
Industrial Control Rooms: Integrated into motor control centers or automation systems, where proximity to sensitive electronics demands non-conductive, low-maintenance power conversion.
2. Moderate Climate & Low-Moisture Zones
They thrive in ambient temperatures ranging from -25°C to +40°C with relative humidity ≤95% (non-condensing), suitable for:
Mild Outdoor Environments (with IP-rated enclosures, e.g., IP20–IP54): Deployed in outdoor substations of urban areas, campuses, or light-industrial zones, protecting against dust, water splashes, and minor physical impacts.
Temperate Regions: Avoiding extreme heat/cold or high humidity, where their air-cooled design (natural or forced ventilation) efficiently dissipates heat without liquid coolant.
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Product productive process
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load

In addition to providing convenience for People's Daily electricity needs in the city, substations are also widely used in wind farms, photovoltaic power stations, hydropower stations, nuclear power plants, hub substations, important converter stations, backbone power grids, important transmission channels and other energy infrastructure scenarios.
 
Work shop
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Certifications
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
Sc (B) 10-400 400kVA Money-Saving Dry Transformer – 980W Loss, 4880W Load
FAQ
1. What are the main products of your company?
We specialize in the production and supply of power transformers, distribution transformers, dry-type transformers, pad-mounted transformers, and single-phase transformers.
2. When will you deliver the goods?
Our production timeline ranges from 45-60 days, contingent on the specifics of the buyer's order.
3. Can you provide samples?
Unfortunately, we are unable to provide samples free of charge.
4. May I have your catalogue and price list?
Absolutely. Please contact us to obtain our comprehensive catalogue and detailed price list.
5. Can your products be customized?
Yes, we excel in producing and processing products tailored to your precise requirements.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now